GD-2134E is a higher-functionality underground steel pipeline detection system composed of sign transmitters and receivers. It can be employed for route detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can have out uniqueness identification with a selection of chosen equipment, as effectively as pipe insulation harm and the search for some kinds of cable faults.

Characteristics

  • EPT exhibit: intuitively displays the pipeline location and remaining & right instructions.
  • Monitoring accurate and bogus prompts: current direction measurement, tracking appropriate mistake prompts, eliminating line interference (some frequencies).
  • Depth and existing measurements, can display the sign toughness historical curve.
  • Totally electronic high-precision sampling processing: steady and trustworthy, extremely-high sensitivity, slim getting passband, EPT anti-interference capability, can fully suppress the electrical power frequency and harmonic interference of adjacent running cables and pipelines.
  • Managing cable detection: substantial-performance transmission clamps, highest coupling output signal to the running cable.
  • Cable/pipeline identification: Flexible clamps (optional) are effortless to use and evidently give identification outcomes stethoscopes (optional) can be employed when it is not handy to use clamps.
  • Ground fault finding: HV booster (optional) boosts the highest output voltage to 1000V, uses the A body (optional) to identify the ground insulation breakage details of the pipeline, no need to adjust zero. The arrow suggests the route of the fault level.
  • Numerous detection frequencies: energetic detection and passive detection.
  • A selection of sign output of the transmitter: immediate connection output, clamp coupling output, radiation induction.
  • High energy output of transmitter, a number of output adjustable, automated impedance matching and safety.
  • Constructed-in massive capability lithium ion battery group, it will computerized shutdown undervoltage or lengthy time no operation,
  • Rugged scenario, gentle and transportable.

 

Requirements

Transmitter

Output modes Immediate connection output, radiation induction, clamp coupling output(optional), fault locating HV booster(optional).
Output frequency 640Hz (compound frequency), 1280Hz (compound frequency), 10kHz, 33kHz, 82kHz, 197kHz.
Output electricity Max.10W, 10 gears adjustable, computerized impedance matching.
Direct connection output voltage Greatest 150Vpp.
Protection Overload and quick circuit defense.
Gentleman-device interface 320 x240 dot matrix Lcd screen.
Built-in battery four section 18650 lithium ion battery, nominal 7.4V, 6.8Ah.

Receiver

Enter mode Developed-in receiving coil, adaptable clamp-on CTs(optional), Stethoscope(optional), A kind fault detection device(optional).
Obtaining frequency
Active detection frequency for Pipes 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.
 
Electrical power frequency passive detection frequency 50Hz/60Hz and 250Hz/300Hz (person configurable).
RF passive detection frequency The middle frequency is 10kHz, 33kHz, 82kHz respectively.
Pipe detection manner Extensive peak approach, slim peak technique, seem Valley method.
Cable identification mode Adaptable clamp-on CTs(optional) automated identification and current measurement, stethoscope(optional) identification.
Exhibit 320*240 Lcd exhibit, shows signal amplitude, remaining/correct course, correct/fake indication, heritage curve of sign strength, depth, recent and end result.
Battery Built-in battery, two part 18650 lithium ion battery, rated seven.4V, three.4Ah.

Other people

Dimension Transmitter 280*220*90mm. Receiver 680*277*120mm.·
Weight Transmitter two.3kg. Receiver 2.0kg.
Charger AC100-240V input, 50/60Hz, output DC 8.4V,2A/3A.
Doing work problem Temperature -10-40ºC, humidity five-90%RH, altitude<4500m

 

/ The use of original products manufacturer’s (OEM) part quantities or logos , e.g. CASE® and John Deere® are for reference needs only and for indicating solution use and compatibility. Our company and the outlined EPT components contained herein are not sponsored, approved, or produced by the OEM. /